As horizontal water barrier in- and under walls and as
adhesion bridge on critical surfaces.
Protects underground structures according to DIN 18533
permanently against W1-E, W2.1-E, W3-E and W4-E.
Fully usable according to the requirements of DIN EN 15814.
Useable in and under walls according to the FPD test principles in
load case 2 (LF2). Useable as protection against radon radiation
on and under structures below ground.
* These times may vary greatly, depending on humidity, temperature, coating thickness and substrate. Times are based on the standard climate of + 23 °C and 50 % relative humidity.
** Temperature: component, installation and ambient temperature
Dry layer thickness | Wet layer thickness* | Consumption* |
---|---|---|
2,0 mm | 2,1 mm | 2,5 kg/m² |
3,0 mm | 3,2 mm | 3,8 kg/m² |
4,0 mm | 4,3 mm | 5,2 kg/m² |
Scratch coating | - | 1-2 kg/m² |
Gluing insulation and drainage panels | - | 1-2 kg/m² |
* The consumption rates shown are minimum values. A separate professional levelling of the substrate, for example by a scratch coating is expected.
Technical Service
+49 5237 608-119 oder
+49 5237 608-138
awt@bitumentechnik.de
Sales
+49 5237 608-139
vtrasco@bitumentechnik.de